Á¦  Á¶ »ç : Blue-White Industries Ltd
»ç¿ë¹üÀ§ : ¸¸°ü»óÅÂÀÇ ¸ðµçÀ¯Ã¼ ÃøÁ¤
¿ë      µµ : ÈÞ´ë¿ë ¹× ¼³Ä¡¿ë À¯·®°è
¸®½ºÆ®
 
»ó¼¼Á¤º¸ Detail View

Sonic-Pro Hybrid Ultrasonic Flowmeters,S3 Serise 

High quality 320 x 240 pixel QVGA backlit LCD display. Five button, fully configurable, tactile switch

keypad interface.

Security: master & configuration passwords. 

 

< Features >

  • User-selectable Doppler or Transit Time operating modes for measurement of both clean and dirty fluids
  • The meter can be factory configured for easy installation
  • Custom quality metric algorithms and DSP technology for reliable, high accuracy measurements
  • To allow for changes in the fluid¡¯s particle count, SonicPro monitors the signal gain and employs an
    Automatic Gain Control (AGC) algorithm that periodically adjusts the gain, maintaining the optimum power level
  • Smart external communication with simple, intuitive, Sonic-Pro software
  • Portable, rugged carrying case for easy transportation between applications
  • 2 year factory warranty
  •  

    < Specifications >

    Pipe size  :  T-Track fitting allows for small pipe diameter capabilities (1/2¡±-24¡±)

                      Pipe size range ¨ö¡±-100¡±

    Fluid  :   Virtually any acoustically conductive fluid, Dirty or Clean

    Doppler mode  :  Requires particles to be present in the flow stream to ¡°reflect¡± the sound waves.

                                                                                                      (ie. Air bubbles, sand, etc.)

                             Opernaration Environment  :  fluid contains .02%-15% (200-150,000 ppm) of particles.

    Transit time mode  :  Requires relatively ¡°clean¡± fluid to enable the sound waves to complete a circuit.

                                   Optional Environment  :  0%-10% (0-100,000 ppm) of particles.

    Accuracy  :  +/- 1% of rate in Transit-Time mode greater than 1 ft/sec fluid velocity

                      +/- 0.01 ft/sec in Transit-Time mode less than 1ft/sec fluid velocity

                      +/- 2% of rate in Doppler mode greater than 5 ft/sec fluid velocity

                      +/- 0.10 ft/sec in Doppler mode less than 5 ft/sec velocity

    Interface & Date

     - Optional process Control  :  Three independently configurable 10 amp, form C relays. Configure to flow
                       rate for high/low/range rate alarm for to flow total for wither manual trigger

                       batch operations of flow triggered batch operations.

                           4-20 mA output: Fully configurable

                           0 – 1000Hz Pulse Output : Fully configurable

     - Optional Computer Connection: Ethernet, USB, RS-232, RS-485. Permits remote access and control of
    all functions including real-time display, system configuration, data logging, remote data capture as

    well as control functions. Software permits remote internet access through local network setup.

     - Data logging: to standard SD Card supplied with unit. User configurable to time interval, flow rate and
    total set-point triggers. 500,000 events with included 32MB SD Card.

     

     Enviroment NEMA 4X (IP66), Powder Coated aluminum, SS clamps & hardware

     Demensions  :  Meter size = 11¡± H x 8 ¨ö¡±W x 5¡± D (279H x 218W x 127D mm)

                             Shipping dimensions = 21¡± H x 17¡± W x 9 ¨ö¡± H

                             Weight =10.9 Kg. Includes carry case, Excludes T-Track fixture

     

     

     

    ÃÊÀ½ÆÄÀ¯·®°è
    Á¦  Á¶ »ç : Blue-White Industries Ltd
    »ç¿ë¹üÀ§ : ¸¸°ü»óÅÂÀÇ ¸ðµçÀ¯Ã¼ ÃøÁ¤
    ¿ë      µµ : ÈÞ´ë¿ë ¹× ¼³Ä¡¿ë À¯·®°è

    Sonic-Pro Hybrid Ultrasonic Flowmeters,S3 Serise 

    High quality 320 x 240 pixel QVGA backlit LCD display. Five button, fully configurable, tactile switch

    keypad interface.

    Security: master & configuration passwords. 

     

    < Features >

  • User-selectable Doppler or Transit Time operating modes for measurement of both clean and dirty fluids
  • The meter can be factory configured for easy installation
  • Custom quality metric algorithms and DSP technology for reliable, high accuracy measurements
  • To allow for changes in the fluid¡¯s particle count, SonicPro monitors the signal gain and employs an
    Automatic Gain Control (AGC) algorithm that periodically adjusts the gain, maintaining the optimum power level
  • Smart external communication with simple, intuitive, Sonic-Pro software
  • Portable, rugged carrying case for easy transportation between applications
  • 2 year factory warranty
  •  

    < Specifications >

    Pipe size  :  T-Track fitting allows for small pipe diameter capabilities (1/2¡±-24¡±)

                      Pipe size range ¨ö¡±-100¡±

    Fluid  :   Virtually any acoustically conductive fluid, Dirty or Clean

    Doppler mode  :  Requires particles to be present in the flow stream to ¡°reflect¡± the sound waves.

                                                                                                      (ie. Air bubbles, sand, etc.)

                             Opernaration Environment  :  fluid contains .02%-15% (200-150,000 ppm) of particles.

    Transit time mode  :  Requires relatively ¡°clean¡± fluid to enable the sound waves to complete a circuit.

                                   Optional Environment  :  0%-10% (0-100,000 ppm) of particles.

    Accuracy  :  +/- 1% of rate in Transit-Time mode greater than 1 ft/sec fluid velocity

                      +/- 0.01 ft/sec in Transit-Time mode less than 1ft/sec fluid velocity

                      +/- 2% of rate in Doppler mode greater than 5 ft/sec fluid velocity

                      +/- 0.10 ft/sec in Doppler mode less than 5 ft/sec velocity

    Interface & Date

     - Optional process Control  :  Three independently configurable 10 amp, form C relays. Configure to flow
                       rate for high/low/range rate alarm for to flow total for wither manual trigger

                       batch operations of flow triggered batch operations.

                           4-20 mA output: Fully configurable

                           0 – 1000Hz Pulse Output : Fully configurable

     - Optional Computer Connection: Ethernet, USB, RS-232, RS-485. Permits remote access and control of
    all functions including real-time display, system configuration, data logging, remote data capture as

    well as control functions. Software permits remote internet access through local network setup.

     - Data logging: to standard SD Card supplied with unit. User configurable to time interval, flow rate and
    total set-point triggers. 500,000 events with included 32MB SD Card.

     

     Enviroment NEMA 4X (IP66), Powder Coated aluminum, SS clamps & hardware

     Demensions  :  Meter size = 11¡± H x 8 ¨ö¡±W x 5¡± D (279H x 218W x 127D mm)

                             Shipping dimensions = 21¡± H x 17¡± W x 9 ¨ö¡± H

                             Weight =10.9 Kg. Includes carry case, Excludes T-Track fixture

     

     

     

    ¸®½ºÆ®
    02-2634-8186  »ó´ãÀüÈ­
    »ó´ãÀüÈ­ 02-2634-8186
    ÇÑÀÏÇǾØÀÌ(ÁÖ)   /   ÁÖ¼Ò : ¼­¿ïƯº°½Ã ¸¶Æ÷±¸ µ¶¸··Î 331. ¸¶½ºÅÍÁö 804È£   /   »ç¾÷ÀÚµî·Ï¹øÈ£ : 105-04-22063   /   ´ëÇ¥ : ¿©¹Ì°æ
    ÀüÈ­¹øÈ£ : 02-2634-8186   /   Æѽº¹øÈ£ : 02-2634-8180   /   Email : kone8180@naver.com
    COPYRIGHT(C) Koreaone P&E Inc. ALL RIGHTS RESERVED.
    ÇÑÀÏÇǾØÀÌ(ÁÖ) / ´ëÇ¥ : ¿©¹Ì°æ
    ¼­¿ïƯº°½Ã ¸¶Æ÷±¸ µ¶¸··Î 331. ¸¶½ºÅÍÁö 804È£
    »ç¾÷ÀÚµî·Ï¹øÈ£ : 105-04-22063
    ÀüÈ­ : 02-2634-8186   /   Æѽº : 02-2634-8180
    COPYRIGHT(C) Koreaone P&E Inc.